Siemens 7me6520 overview
Siemens 7me6520 is an electromagnetic flowmeter.
The siemens 7me6520 electromagnetic flowmeter is a device for measuring the flow of conductive liquids. It uses Faraday’s principle of electromagnetic induction, to calculate flow by measuring the induced electromotive force generated in a magnetic field when a fluid flows. This flowmeter is suitable for a variety of application scenarios including but not limited to industrial needs such as groundwater, drinking water, sewage and sludge treatment. The design takes into account the special requirements of various industrial environments to ensure the accuracy and reliability of measurement.
Features
siemens 7me6520 electromagnetic flowmeter has the following characteristics:
caliber DN100, to meet the needs of different pipeline sizes.
sensor material is carbon steel, has good corrosion resistance and mechanical strength.
The electrode material is Hastelloy C-276, for stability and durability under extreme conditions.
Includes a grounded electrode, for increased safety.
The Metric Polyamid or 6000 I compact terminal box is available, suitable for different installation environments.
Specification
The specifications of Siemens electromagnetic flowmeter 7ME6520 include caliber DN800, size 32 inches, conforming to EN 1092-1 standard, working pressure PN 10, material including Carbon steel ASTM A 105, electrode material is Hastelloy C-276, including ground electrode. sensor is suitable for remote transmitters, a separate transmitter order is required. The terminal box is Metric Polyamid or 6000 I compact.
Methods of using electromagnetic flowmeters
Preparations before installation: Check that the sensor model matches the measurement media and application scenario. Check that the sensor and its accessories are intact. Obtain necessary tools and materials.
Installation: According to the installation guide, install the sensor in the appropriate position, ensure that the fluid flow in the measuring pipe is stable, no bubbles and eddies. Connect the sensor to the power supply, signal output, and other devices. pay attention to the correctness and safety of cable connections.
debugging and calibration: According to the sensor instructions, carry out necessary debugging and calibration work, to ensure the accuracy of measurement results. Check the working status of the sensor, and ensure that there is no leakage, and no abnormal vibration and noise.
Use and maintenance: During the use, regularly check the operating status and measurement data of the sensor, timely detect and handle abnormal conditions. , clean and maintain the sensor as needed, and keep it in good working condition.
Precautions: During the installation and use, must comply with the relevant safety regulations and operating procedures, to ensure the safety of personnel and equipment. Avoid exposing the sensor to extreme temperatures, humidity and corrosive environments to avoid compromising its performance and life.
Siemens 7me6520 datasheet
Related model numbers
7me6520-3mc13-2aa1
7me6520-4hc12-2aa1
7me6520-2yc13-2aa1
7me6520-3tc12-2aa1
7me6520-4hc13-2aa1
7me6520-2yc12-2aa1
7me6520-3mc12-2aa1
7me6520-3tc13-2aa1
7me6520-4pc13-2aa1